Measured value data records
E.2 Measured value data record for base measurements (DS 142)
Analog input module AI Energy Meter 480VAC/CT HF (6ES7134-6PA00-0CU0)
228 Manual, 07/2018, A5E42674880-AA
Byte
Measured variable
Data
type
Unit
Value range
Meas-
ured
value
ID
90...93
Reactive power Qtot L3
REAL
var
-3.0 x 10
9
… +3.0 x 10
9
24
94...97 Total reactive power Qtot L1L2L3 REAL var -3.0 x 10
9
… +3.0 x 10
9
38
98...101
Active power L1
REAL
W
-3.0 x 10
9
… +3.0 x 10
9
13
102...105 Active power L2 REAL W -3.0 x 10
9
… +3.0 x 10
9
14
106...109
Active power L3
REAL
W
-3.0 x 10
9
… +3.0 x 10
9
15
110...113
Total active power L1L2L3
REAL
W
-3.0 x 10
9
… +3.0 x 10
9
34
114...117
Phase angle L1
REAL
°
0.0 ... 360.0
61178
118...121
Phase angle L2
REAL
°
0.0 ... 360.0
61198
122...125
Phase angle L3
REAL
°
0.0 ... 360.0
61218
126...129
Total apparent energy L1L2L3
REAL
VAh
0.0 ... 3.4 x 10
38
204
130...133
Total reactive energy L1L2L3
REAL
varh
-3.4 x 10
38
to +3.4 x 10
38
206
134...137
Total active energy L1L2L3
REAL
Wh
-3.4 x 10
38
to +3.4 x 10
38
205
138...141
Total reactive energy inflow L1L2L3
REAL
varh
0.0 ... 3.4 x 10
38
202
142...145
Total reactive energy outflow L1L2L3
REAL
varh
0.0 ... 3.4 x 10
38
203
146...149
Total active energy inflow L1L2L3
REAL
Wh
0.0 ... 3.4 x 10
38
200
150...153
Total active energy outflow L1L2L3
REAL
Wh
0.0 ... 3.4 x 10
38
201
154...161
Total apparent energy L1L2L3
LREAL
VAh
0.0 ... 1.8 x 10
308
214
162...169
Total reactive energy L1L2L3
LREAL
varh
-1.8 x 10
308
to +1.8 x 10
308
216
170...177
Total active energy L1L2L3
LREAL
Wh
-1.8 x 10
308
to +1.8 x 10
308
215
178...185
Total reactive energy inflow L1L2L3
LREAL
varh
0.0 ... 1.8 x 10
308
212
186...193 Total reactive energy outflow L1L2L3 LREAL varh 0.0 ... 1.8 x 10
308
213
194...201
Total active energy inflow L1L2L3
LREAL
Wh
0.0 ... 1.8 x 10
308
210
202...209
Total active energy outflow L1L2L3
LREAL
Wh
0.0 ... 1.8 x 10
308
211
210...213
Neutral current
REAL
A
0.0 ... 100000.0
61149
Neutral current
If you operate the AI Energy Meter HF with connection type 3P4W, 3P4W1 or 3P3W, the
neutral current is also calculated under the following conditions:
Transmission factors of all phase currents (primary and secondary currents) are identical.
Measured phase currents are greater than the value of the "Low limit for measuring
current parameter.
The parameter "Reverse current direction" must be the same on all phases.
If one of the conditions is not met, 0 is entered as the value for the neutral current. You can
read the neutral current calculated using measured value data record 142.

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP and is the answer not in the manual?

Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)
Operating Temperature-25°C to +60°C