EasyManuals Logo

Siemens SIMATIC HMI IPC677C User Manual

Siemens SIMATIC HMI IPC677C
282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #165 background imageLoading...
Page #165 background image
Alarm, error, and system messages
12.3 BIOS beep codes
SIMATIC HMI IPC677C
Operating Instructions, 04/2013, A5E02722710-04
165
Display
(hex)
Meaning Description Remedy
4FH DXE_MP_CPU_INIT Multi-processor
Middle Initial
Multiprocessor
initialization
Replace basic
module
50H DXE_SMBUS_INIT SMBUS Driver
Initial
SMBUS driver
initialization
Service case
51H DXE_SMART_TIMER_INIT 8259 Initial SMART Timer
initialization
Service case
52H DXE_PCRTC_INIT RTC Initial RTC initialization Service case
53H DXE_SATA_INIT SATA Controller
early initial
Advance initialization of
the SATA Controller
Service case
54H DXE_SMM_CONTROLER_INIT Setup SMM
Control service,
DXE_SMMContr
oler_INIT
SSM Control service Service case
55H DXE_LEGACY_INTERRUPT Setup Legacy
Interrupt service,
DXE_LegacyInte
rrupt
Setup Legacy Interrupt
service
Service case
01H SEC_SYSTEM_POWER_ON CPU power on
and switch to
Protected mode
Switch to Protected
Mode
Service case
02H SEC_BEFORE_MICROCODE_PATCH Patching CPU
microcode
Load CPU Microcode Service case
03H SEC_AFTER_MICROCODE_PATCH Setup Cache as
RAM
Set up cache as RAM Service case
04H SEC_ACCESS_CSR PCIE MMIO
Base Address
initial
Initialize PCIE Service case
05H SEC_GENERIC_MSRINIT CPU Generic
MSR initial
Initialize CPU MS
(Machine Status)
Register
Service case
06H SEC_CPU_SPEEDCFG Setup CPU
speed
Specify CPU speed Service case
07H SEC_SETUP_CAR_OK Cache as RAM
test
Carry out RAM Test on
cache
Replace basic
module
08H SEC_FORCE_MAX_RATIO Tune CPU
frequency ratio
to maximum
level
Setting CPU frequency Service case
09H SEC_GO_TO_SECSTARTUP Setup BIOS
ROM cache
Set up BIOS ROM
cache
Service case
0AH SEC_GO_TO_PEICORE Enter Boot
Firmware
Volume
Calling up the boot
firmware memory area
Service case
70H PEI_SIO_INIT Super I/O initial Initialization of the
Super I/O
Service case
71H PEI_CPU_REG_INIT CPU Early Initial Initialize CPU Register Service case
72H PEI_CPU_AP_INIT Multi-processor
Early initial
Multi processor
initialization
Service case

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC HMI IPC677C and is the answer not in the manual?

Siemens SIMATIC HMI IPC677C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC HMI IPC677C
CategoryIndustrial PC
LanguageEnglish

Related product manuals