Operation and configuration
8.2 Normal operation
SIMATIC HMI IPC677C
Operating Instructions, 04/2013, A5E02722710-04
79
8.2 Normal operation
8.2.1 Switching on the device
Requirement
The peripheral devices are connected.
NOTICE
To comply with the EMC guideline of the device with I/O, ensure that the manufacturer
or supplier of the components used guarantees compliance with the regulations.
Connect the I/O devices via shielded cables with metal connectors. In doing so, the
shield must be connected over a wide area with the metal connector and the connector
must be firmly connected with the device housing.
The operating system and the service packs have been installed and set up on the hard
disk of the device. Refer to the "Commissioning" chapter for more information.
The pre-installed drivers and applications have been set up appropriately. Further
information is available in the "Operation and configuration" chapter in the section,
"Additional drivers and applications."
The proper ambient and environmental conditions according to the specifications for the
device and the connected I/O modules have been observed.