Technical data
14.1 General specifications
SIMATIC HMI IPC677C
178 Operating Instructions, 04/2013, A5E02722710-04
Safety 12" TFT
Key panel
15" TFT
Key panel
12" TFT
Touch panel
15" TFT
Touch panel
19" TFT'
Touch panel
15" INOX
Touch panel
Degree of protection
• IP65/Enclosure Type 4 with clamp mount, encircling seal and pressed-
on plastic cap for USB port*
)
• IP54 with screw fastening
IP66K, fastening
with anchor
clamps
Protection class Protection class I according to IEC 61140
Safety regulations IEC/EN/DIN EN 60950-1
Certifications cULus in accordance with UL 508
Conformity CE
Liability of product
nonconformance
24 months
Quality assurance According to ISO 9001
*
)
The front USB port cannot be used in some devices.
Permissible temperature ranges depend on the type of installation
Temperature ranges
Complete unit Temperature
in cabinet
Ambient
temperature
Cabinet
Comment
Installed in cabinet, different
temperatures
50 °C 40 °C
• Maximum PCI load 15 W
• Optical drives may not be operated
with a temperature > 40° C.
Installed in cabinet, same temperature
inside and outside
45 °C 45 °C
• Complete configuration, maximum
PCI load 30 W (2 slots)
These values are applicable for vertical installation and when air is flowing through the cabinet.
Electromagnetic compatibility (EMC)
Interference emission EN 61000-6-4 Class A
EN 61000-3-3, FCC Class A
Interference immunity:
Conducted disturbance variables on supply lines
± 2 kV, according to IEC 61000–4–4, burst
± 1 kV, according to IEC 61000–4–5, surge sym.
± 2 kV, according to IEC 61000–4–5, surge asym.
Interference immunity on signal lines ± 1 kV, according to IEC 61000–4–4, burst, length < 30 m
± 2 kV, according to IEC 61000–4–4, burst, length > 30 m
± 2 kV, according to IEC 61000–4–5, surge, length > 30 m
Immunity to discharges of static electricity ± 6 kV contact discharge according to IEC 61000–4–2
± 8 kV air discharge according to IEC 61000–4–2
Immunity to RF interference ± 2 kV, (according to IEC 61000-4-4; burst)
± 1 kV; (according to IEC 61000-4-5; surge sym.)
± 2 kV; (according to IEC 61000-4-5; surge asym.)
Magnetic field 100 A/m, 50 Hz according to IEC 61000–4–6