Operation and configuration
8.3 Additional drivers and applications
SIMATIC HMI IPC677C
90 Operating Instructions, 04/2013, A5E02722710-04
SetBrightness.exe –ACTION [VALUE] [-device DEVICENUMBER]
Note
In contrast to the graphical interface, the minimum value is set to 0% in command line mode.
In this case, the display is switched off. By pressing an input device, for example touch or
keyboard, the display is switched on again and set to the most recent configured brightness
level. The first input event, for example a mouse click, is discarded in this case to avoid the
triggering an unintended action.
Parameter –ACTION [VALUE]
The "ACTION" parameter must be specified for each command line call of the
"SetBrightness" program. The following options are available for selection:
Value Explanation
–get Returns the currently set brightness. There must not be any other value
specified for VALUE.
–set The brightness value specified by VALUE (0-100) is applied.
–getdevicecount Supplies the number of connected displays. There must not be any other
value specified for VALUE.
Option [–device DEVICENUMBER]
The "device" option can be specified for the command line call of the "SetBrightness"
program. It specifies the number of the display for which the current brightness is to be read
out or set. If the option is not used, the Display with the number 1 is always used. The
following are examples of this:
SetBrightness –get Returns the brightness of display "1".
SetBrightness –set 50 –device 2 Sets the brightness of display "2" to 50%.
Advanced options -plugin PLUGINNAME
To increase the execution speed, it can be specified explicitly for the command line call that
not all available plugins are loaded, but rather only the plugin indicated by PLUGINNAME.
Notice: The respective numbers of the operable displays are shifted accordingly. Example:
SetBrightness.exe –set 75 –device 2
–plugin FPPlugin.dll
Sets the brightness of display "2" to 75%. Only the
"FPPlugin.dll" plugin is loaded.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC HMI IPC677C and is the answer not in the manual?

Siemens SIMATIC HMI IPC677C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC HMI IPC677C
CategoryIndustrial PC
LanguageEnglish

Related product manuals