Installing and connecting the device
3.3 Connecting the device
SIMATIC IPC BX-39A
Operating Instructions, 07/2022, A5E50715883-AA
45
3.3.6 Securing the lines
The strain relief (see "Scope of delivery (Page 26)") is used to prevent accidental loosening of
the interface cable from the device.
Requirements
I/O devices are connected to the respective interfaces.
1 screwdriver of the type Torx T10
1 strain relief
Cable ties (not included in the scope of delivery)
3 screws
Procedure
1.
Fasten the strain relief at the designated
points
with the supplied oval head
screws.
2.
Pass the cable tie around the strain relief
bar and secure the cables as shown.
3.
Cut off the protruding ends of the cable
ties.