Mounting and connecting the device 
  3.3 Connecting the device 
SIMATIC IPC PX-39A PRO 
Operating Instructions, 11/2022, A5E51699950-AA  
55 
3.3.2.3  Connecting the 24 VDC power supply 
Requirements 
•  The device is installed. 
•  The protective conductor (Page 54) is connected. 
•  The connection terminal is wired. 
•  The corresponding 24 V DC power supply is switched off. 
•  A two-core copper cable with a cable cross-section of ≥ 0.5 mm
2
 for the 24 V DC 
connection. 
The two-core copper cable must be suitable for temperatures of at least 95 °C. 
•  A slotted screwdriver with approx. 3 mm blade. 
Procedure 
 
 
Switch off the 24 V DC power sup-
ply. 
 
Connect the wires of the power 
supply. 
 
Plug the connecting terminal into 
the connection socket at the indi-
cated position. 
The connecting terminal must 
snap into the connection socket. 
 
Secure the power supply cable to 
the strain relief with a cable tie.