Mounting and connecting the device
3.2 Mounting the device
SIMATIC IPC PX-39A PRO
46 Operating Instructions, 11/2022, A5E51699950-AA
3.2.3 Prepared for support arm and extension elements (flange mount)
Requirements
All packaging components and protective films have been removed.
The cover plate of the PRO device is ready.
One of the following support arm systems:
Support arm with round tube end with an external diameter of 48.3 mm +/-0.5 mm,
appropriate for the opening of the PRO device
When selecting the round tube adapter, ensure its inner diameter is large enough to
allow all required cables and their connectors to pass through.
Support arm with mechanical interface, appropriate for the flange of the round tube
adapter, and Siemens round tube adapter (not included in product package)
Support arm with mechanical VESA interface, the corresponding Siemens adapter set
and the Siemens round tube adapter (not included in product package)
See "System components (Page 19)"
The following cables are fed through the support arm to which the device is mounted:
Protective conductor
Power supply cable
Data cables, e.g. USB
Note
Route cables with large plugs through the pedestal or support arm first.
Procedure
NOTICE
Observe the torques
If you apply too much torque to tighten the screws of the backplane cover and the terminal
compartment cover or the screws for fastening the device to a support arm or pedestal, the
threads of the enclosure, intermediate plate or support arm may be damaged.
If you tighten the screws with a torque that is too low, the device is not sealed.