Previous versions
C.1 Previous MDS version with different MLFB
MOBY D
System Manual, 01/2010, J31069-D0147-A6-7618
303
Technical data
Table C- 2 Technical data for MDS D124
Memory size 128 bytes
Memory configuration
ï‚· Serial number
ï‚· Configuration memory
ï‚· AFI/DSFID
ï‚· Application memory
ï‚· 8-byte (fixed code)
ï‚· 6 bytes
ï‚· 2 bytes
ï‚· 112 bytes
Storage technology EEPROM
Memory organization See the Section
Mobile data storage units -
Introduction
Listing to ISO 15693
Data contents (at +40°C) 10 years
MTBF (at +40 °C) ≥ 1.5 x 10
6
hours
Data transmission rate
ï‚· Read
ï‚· Writing
ï‚· approx. 3,5 ms/byte
ï‚· approx. 9.5 ms/byte
Read cycles Unlimited
Write cycles, typical 1 000 000
Write cycles, min. 200 000
Write/read distance (S
g
) See the Section
Field data
Distance from metal min. 25 mm (approx. 30 % reduction of the field
data)
Multitag capability Yes
Anti-collision speed approx. 20 transponders/s simultaneously
identifiable
Power supply Inductive power transmission
(without battery)
Degree of protection to EN 60529 IP67
Shock resistant to EN 60721-3-7, Class 7M3
total shock response spectrum, Type II
100 g
Vibration-resistant to EN 60721-3-7, Class
7M3
20 g
Torsion and bending load Not permissible
Dimensions (D x H) in mm 27 x 4
Color Black
Material Epoxy casting resin
Mounting technique Adhesive, M3 screw
Tightening torque at +20 °C ≤ 1 Nm
(at high temperatures, the expansion coefficients of
the materials used must be taken into account)