Antenna attachment 4 x M5 screws
Ambient temperature
ï‚· Operation
ï‚· Transport and storage
 -25 °C to +55 °C
 -25 °C to +70 °C
MTBF
ï‚· SLG D11
ï‚· ANT D5
ï‚· 2.0 x 10
5
hours
ï‚· 3.0 x 10
5
hours
Degree of protection to EN 60529
ï‚· SLG and antenna
IP65 (UL: for indoor only)
Shock resistant to EN 60721-3-7
Class 7M2 Total shock response
spectrum, Type II
30 g
Vibration compliant with
EN 60721-3-7, Class 7M2
1 g (9 to 200 Hz)/1.5 g (200 to 500 Hz)
Weight, approx.
ï‚· SLG
ï‚· Antenna
ï‚· 600 g
ï‚· 1000 g
Approvals
ï‚· CE
ï‚· FCC
ï‚· IC
ï‚· Harmless to heart pacemakers
ï‚· UL 60950
1) In order to guarantee optimum field data even in the vicinity of metal, ANT D5 is calibrated at the
factory at a distance of 100 mm from metal.
CAUTION
The antenna cable is permanently preassembled. Any modifications made to the cable will
invalidate both the warranty and the CE approval.
Note
The SLG D11 can process up to 4 MDSes with I-Code 1-Chip (e.g. MDS D139) in multitag
mode!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC MOBY D and is the answer not in the manual?

Siemens SIMATIC MOBY D Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC MOBY D
CategoryAccessories
LanguageEnglish

Related product manuals