Planning the MOBY D system 
  4.3 Installation guidelines 
MOBY D 
System Manual, 01/2010, J31069-D0147-A6-7618 
41 
ANT D5 
ANT D5 must be mounted electrically isolated, direct mounting on metal is not permitted. 
The maximum field data (no interference = 100 %) are achieved when the antenna ANT D5 
is mounted at a distance of 100 mm from metal (spacer kit 6GT2690-0AB00).  
0HWDO
K PPQRQPHWDOVSDFHU
 
Figure 4-9  ANT D5: Insulated mounting on metal  
 
1RQPHWDOVSDFHU
0HWDO
PP
PP
PP
 
Figure 4-10  ANT D5: Installation in metal  
See also Subsection 
Influencing the transmission window
. 
ANT D6/D10 
Mounting on metal permitted. Typical distances from metal are indicated in the section 
Metal-free area
 in the chapter 
write/read devices
.