Open loop motion control
12.6 Subroutines created by the Motion wizard for the Axis of Motion
S7-200 SMART
620 System Manual, V2.3, 07/2017, A5E03822230-AF
12.6
Subroutines created by the Motion wizard for the Axis of Motion
You must ensure for each motion action that only one motion subroutine is active at a time in
addition to the AXISx_CTRL, which must be active every scan. Each motion subroutine is
prefixed with an "AXISx_" where "x" is the axis number channel. There are 13 motion
subroutines.
Motion subroutine
Description
AXISx_CTRL
(Page 622)
Provides initialization and overall control of the axis
AXISx_MAN
(Page 623)
Used for manual mode operation of the axis
AXISx_GOTO
(Page 625)
Commands the axis to go to a specified location
AXISx_RUN
(Page 626)
Commands the axis to execute a configured motion profile
AXISx_RSEEK
(Page 627)
Initiates a reference point seek operation
AXISx_LDOFF
(Page 628)
Establishes a new zero position that is offset from the reference point position
AXISx_LDPOS
(Page 629)
Changes the axis position to a new value
AXISx_SRATE
(Page 630)
Modifies the configured acceleration, deceleration, and jerk compensation
times
AXISx_DIS
(Page 631)
Controls the DIS output
AXISx_CFG
(Page 632)
Reads the configuration block and updates the axis setup as required
AXISx_CACHE
(Page 633)
Pre-caches a configured motion profile
AXISx_RDPOS
(Page 634)
Returns the current axis position
AXISx_ABSPOS
(Page 635)
Reads the absolute position value from a SINAMICS V90 servo drive
Note
The motion subroutines increase the amount of memory required for your program by up to
1700
bytes. You can delete unused motion subroutines to reduce the amount of memory
required. To prevent the generation of unneeded motion subroutines, uncheck the
"Generate" box for each unneeded subroutine in the "Components" node of the Motion
wizard. To restore generation of a particular motion subroutine, start the Motion wizard
a
gain, navigate to the "Components" node, and check the "Generate" box for the subroutine.
Click the "Generate" button to rebuild the wizard
-generated subroutines.
See also
Using the Motion wizard (Page 595)

Table of Contents