Interrupt events in priority order
Table E- 2 Priority order for interrupt events
Communications
Highest Priority
9 Port 0 Transmit complete
Port 0 Receive message complete
24 Port 1 Receive message complete
Discrete
Medium Priority
PTO0 Pulse count complete
PTO1 Pulse count complete
PTO2 Pulse count complete
I7.0 Rising edge (signal board)
I7.1 Rising edge (signal board)
I7.0 Falling edge (signal board)
38 I7.1 Falling edge (signal board)
HSC0 CV=PV (current value = preset value)
HSC1 CV=PV (current value = preset value)
HSC2 CV=PV (current value = preset value)
17 HSC2 Direction changed
HSC3 CV=PV (current value = preset value)