EasyManua.ls Logo

Siemens SIMATIC TeleControl DNP3 - Lan; Ethernet Interface [Xn]; C.8.1 Ethernet Interface [Xn]

Siemens SIMATIC TeleControl DNP3
192 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WBM of the TIM 1531 IRC
C.8 LAN
Configuration - DNP3
178 Configuration Manual, 11/2018, C79000-G8976-C508-01
C.8
LAN
C.8.1
Ethernet interface [Xn]
● The three Ethernet interfaces of the TIM are selected via the upper tabs.
– X1 ... X3
● The parameters of the selected interface are shown in the lower series of tabs:
– IPv4 parameters
– IPv6 parameters
– Statistics
IPv4 parameters
Network attachment
●
MAC address
IP parameters
●
IP address
Current IP address
●
Subnet mask
Default or last configured subnet mask.
●
Default router
Configured default router
●
Address assignment
Shows how obtaining the IP address is configured in STEP 7:
– Set IP address in the project
– IP address from DHCP server
– Set IP address on the device
The IP address obtained using other services outside the configuration
Ports
●
Port number
Port of the interface
●
Connection status
– OK: Existing connection to the network
– Not OK: No connection

Table of Contents