5
05.01
5.4 ”HLA module” control board
5-136
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 05/2008 Edition
Connection for two pressure sensors per axis
S X111: Axis 1 (sensors 1A, 1B)
S X112: Axis 2 (sensors 2A, 2B)
Table 5-19 Connectors X111, X112; each 15–pin sub–D socket connector
Pin X111 X112 Type
1)
Function
1 P24DS P24DS O External +24 V supply for the
pressure sensor
2 P24DS P24DS O External +24 V supply for the
pressure sensor
3 Not assigned
4 Not assigned
5 M24EXT M24EXT O External 0 V supply for the
pressure sensor
6 Not assigned
7 Not assigned
8 Not assigned
9 M24EXT M24EXT O External 0 V supply for the
pressure sensor
10 M24EXT M24EXT O Extra pin for jumper between pins 10–11 with
3–wire connection
11 PIST1BN PIST2BN I Analog actual value signal, reference ground
12 PIST1BP PIST2BP I Analog actual value signal, max. range 0...10 V
13 M24EXT M24EXT O Extra pin for jumper between pins 13–14 with
3–wire connection
14 PIST1AN PIST2AN I Analog actual value signal, reference ground
15 PIST1AP PIST2AP I Analog actual value signal, max. range 0...10 V
1) I = Input, O = Output
The inputs are differential with 40 k input resistance.
The input voltage range is 0...+10 V.
The supply output has an electronic short–circuit protection function.
The supply output is dimensioned for a total current (4 sensors) of 200 mA.
Supply for pressure sensors with 26.5 V "2% according to the external infeed
at X431.
Notice
The external 26.5 V supply voltage cannot be replaced by a 24 V supply
voltage.