7.4 Line filters for I/R and UI modules
7-227
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) -- 05/2008 Edition
7.4.3 Basic line filter for I/R modules
The basic line filter for I/R modules are designed for use in machines in which
the conducted interference in the frequency range is to be reduced in accor-
dance with EMC regulations.
The machine manufacturer must perform the EMC --compliant CE certification
for the product before it is implemented.
Note
The company that puts the machine on the market takes full responsibility for
ensuring CE EMC conformity and that the basic line filter is used correctly. The
machine manufacturer (OEM) must have the machine conformity confirmed
(e.g. by the EPCOS Company; mailto:emv.labor@epcos.com).
The Basic Line Filters can be used in accordance with the following general
conditions for ensuring CE c onformity with regard to cable--borne interference:
S The machine/system must only be used in industrial networks.
S No.ofaxes<12.
S Total cable lengths <150 m (motor cables, power supply cable between the
line filter and I/R module).
Caution
The connections/terminals may not be interchanged:
S Incoming line supply cable to LINE/NETZ L1, L2, L3
S Outgoing cable to the line reactor to LOAD/LAST L1’, L2’, L3’
If this is not observed, the line filter could be damaged.