EasyManua.ls Logo

Siemens SIMODRIVE 611 digital - Calculation of the DC Link Power (Engineering Sheet)

Siemens SIMODRIVE 611 digital
436 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
05.01
1.3 Engineering a drive
1-34
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 05/2008 Edition
1.3.4 Calculation of the DC link power (engineering sheet)
I
0
(PM)
[A]
n
N
[RPM]
Speed
ratio
Axis
name
Order No. of the motor M
0
[Nm]
I
N
[A]
P
calcFD
[kW]
n/n
N
P
calcFD
[kW]
n/n
N
Range I for P
calc
FD
from 0...1.8 kW
1
2
3
4
5
6
Sum, range I
Range II for P
calc
FD
from 1.8...8.8 kW
1
2
3
4
5
6
Sum, range II
Range III for P
calc
FD
from 8.8...27 kW
1
2
3
4
5
6
Sum, range III
Sum, range I x =
+
K
I
Sum, range II x =
K
II
Sum, range III x =
K
II
+
x 1.1 = kW
DC link power
P
VSA
DC
link
kW
DC link power
P
ZK
FD
kW
DC link power
P
ZK
+
=
n/n
N
Application
scenario
Feed drives 0.4 to 0.7
Robot drives 0.9 to 1
Robot drives
with 1FT
1
Coincidence
factor k per range
Feed axes
per range
11
2 0.63
3
4
0.5
0.38
5
6
0.33
0.28
Fig. 1-6 Engineering sheet to calculate the DC link power PzK