4
05.01
4.2 Operating modes
4-85
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 05/2008 Edition
4.2 Operating modes
S with synchronous motors (FD)
1FT6, 1FK6 and 1FK7 servo motors
1FW6 built–in torque motors (direct drives)
1FN linear motors
S with induction motors (MSD–IM)
1PH main spindle motors
1PM hollowshaft motors for main spindle drives (direct drives)
standard induction motors (sensorless)
If IM operation is selected, only inverter pulse frequencies of
4 kHz and 8 kHz are permissible.
S with synchronous motors (MSD–SRM)
1FE1 main spindle motors
2SP1 motor spindle
Note
For the MSD–SRM operating mode (high–speed MSD synchronous
applications), inverter pulse frequencies are set that differ from the rated
frequencies. This consequently ensures an optimum ratio between the inverter
pulse frequency and the output frequency.
The derating resulting from this should be taken into account when selecting
the power module.
The frequencies relevant when engineering the system should be appropriately
taken from the following documentation.
Reader’s note
Technical data and ordering data, refer to
Reference: /PJFE/ Configuration Manual, 1FE1 Synchronous Built–in
Motors
/BU/ Catalog NC 60 2004
/PMS/ Configuration Manual ECO Motor Spindles for
2SP1 Main Spindle Drives
WEISS GmbH/Operating Instructions ECO Spindle Units Type 2SP1...
Feed drives
Main spindle
drives
4 Power Modules10.0411.05