8.15 Examples of correctly and incorrectly connecting NE
8-318
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) -- 05/2008 Edition
F
N
(X A)
F
N
(T10 A)
1L1
P600
M600
U1 V1 W1 PE
X181
M500
P500
2U1
1U1
2V1
1V1
2W1
1W1
X181
M500
P500
2U1
1U1
2V1
1V1
2W1
1W1
≁
L
K
1)
Filter (X kW)
PE
1L2
1L3
PE
2)
≁
2L1
F
N
(T16 A)
2L2
2L3
Filter (5 kW)
F
N
(T10 A)
Cable
twisted!
Cable
twisted!
Example for
connection of
more than four monitoring modules
NE e.g. NCU PMxx PMxx 5th MM 9th MMPMxx
Correct!
Note:
1) L
2) DC link connection for six-conductor connection to the line supply is not permissible!
Schematic
diagram
Six-conductor connection to the line supply
for more than four monitoring modules
for 5 kW and 10 kW integrated, therefore not necessary here!
K
Connection per line
maximum five
monitoring modules
F
N
(T10 A)
3)
3)
3) Cable protection fuses (PS fuses in the module)
Fig. 8-36 Examples for correct six--conductor connection to the line supply with more than four monitoring modules
connected to a line infeed module (NE module)