SIMODRIVE 611 Configuration Manual (PJU) – 05/2008 Edition
Mounting instructions
The thermally conductive plate can be mounted at any position on the device group.
Ensure that the plate is approx. 100 mm wide and so extends over a neighboring device.
It does not matter whether the plate extends to the right or the left.
The division of the rear–side breakouts to fasten the thermally conductive plate take account of this.
The thermally conductive plate together with the device fastening is screwed to the rear wall.
This does not impair the bus lines and DC link connections.
Fig. 12-59 Thermally conductive plate 6SN1162–0BA01–0AAx (dimension drawing)