4
05.01
4.3 Technical data
4-87
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 05/2008 Edition
Table 4-1 Power modules in the 1–axis version
6SN112j–1AA0j–
3 internal cooling
4 external cooling
1)
0HAj 0AAj 0BAj 0CAj 0DAj 0LAj 0EAj 0FAj 0JAj 0KAj
Mounting frame external
cooling 6SN1162–0BA04–
0AAj 0FAj 0BAj 0CAj 0EAj
Type of cooling Non–
ventilated
Fan
For operation of induction motors
Nominal current I
n
A
eff
3 5 8 24 30 45 60 85 120 200
Current for S6–40% I
S6–40%
A
eff
3 5 10 32 40 60 80 110 150 250
Peak current I
max
A
eff
3 8 16 32 51 76 102 127 193 257
Inverter pulse frequency f
0
kHz 3.2
Derating factor X
L
% 50 55 50 55
Power loss, total P
Vtot
W 30 40 74 260 320 460 685 850 1290 2170
Power loss, internal P
Vint
W 12 16 29 89 32 19 30 100 190 325
Power loss, external P
Vext
W 18 24 45 171 288 441 655 750 1100 1845
For operation of synchronous motors
Nominal current I
n
A
eff
3 5 9 18 28 42 56 70 100 140
Peak current I
max
A
eff
6 10 18 36 56 64 112 140 100 210
Inverter pulse frequency f
0
kHz 4
Derating factor X
L
% 55 50 55
Power loss, total P
Vtot
W 35 50 90 190 300 460 645 730 1300 1910
Power loss, internal P
Vint
W 14 19 35 65 30 25 25 90 170 250
Power loss, external P
Vext
W 21 31 55 125 270 435 620 640 1130 1660
General technical data for the regulated infeed
Input voltage V DC Regulated: 600 V or 625 V DC, unregulated: U
DC
link
=U
Supply
1.35
Maximum output voltage V
eff
U
a_max
= U
DC
link
/1.4
Minimum motor current I
min
5)
A 0.6 1.1 1.8 3.6 5.7 8.5 11 14 21 28
Transistor limit current A 8 15 25 50 80 108 160 200 300 400
Efficiency 0.98
Module width mm 50 100 150 300
2)
Weight, approx. kg 6.5 9.5 13 26 28
Maximum air flow of fan
(volumetric flow, unobstructed
flow per fan) m
3
/hr
– – 19 22 56 2x56 2x56
4)
2x51
3)
– –
Motor connection Connectors Terminals
1) For a module width of 300 mm with external cooling, mounting frames are required that must be separately ordered.
The fan assembly required to mount the built–on fan is included in the scope of supply of the mounting frame.
The built–on fan must be separately ordered! Mounting frames are also available for smaller module widths. However,
these are not required if openings are cut out in the rear cabinet panel for the module heatsinks as shown
in this Configuration Manual.
2) For 6SN1123–1AA0j–0JAj/0KAj and 6SN1124–1AA0j–0FAj/–0JAj/–0KAj, the built–on fan
6SN1162–0BA02–0AA2 is required.
3) For Internal heat dissipation
4) Externally without fan
5) True for induction motors and applies to the no–load current.
4 Power Modules10.0405.08