Technical data and characteristics
6.2 Data sheets and diagrams
1FW6 Built-in torque motors
164 Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
6.2.1
1FW6050-xxxxx-xxxx
Data sheet 1FW6050-xxB03-xxxx
Table 6- 2 1FW6050-xxB03-0Fxx
Technical data
1FW6050
Symbol
Unit
-xxB03-0Fxx
Boundary conditions
DC link voltage
U
DC
V
600
Water cooling inlet temperature
T
VORL
°C
35
Rated temperature of winding
T
N
°C
130
Data at the rated operating point
Rated torque
M
N
Nm
23.2
Rated current
I
N
A
4.87
Rated speed
n
N
rpm
940
Rated power loss
P
V,N
kW
0.769
Limit data
Maximum torque
M
MAX
Nm
34.4
Maximum current
I
MAX
A
7.61
Electric motor power at M
MAX
P
EL,MAX
kW
4.23
Maximum speed
n
MAX
rpm
2820
Maximum speed at maximum torque
n
MAX,MMAX
rpm
697
Max. speed without VPM
n
MAX,INV
rpm
1970
No-load speed
n
MAX,0
rpm
1440
Torque at n = 1 rpm
M
0
Nm
24.2
Current at M
0
and n = 1 rpm
I
0
A
5.09
Thermal static torque
M
0
*
Nm
17.4
Thermal stall current
I
0
*
A
3.6
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
4.87
Voltage constant
k
E
V/(1000/min)
294
Motor constant at 20 °C k
M,20
Nm/(W)
0,5
1.07
Thermal time constant t
TH
s 75
No. of pole pairs
p
-
11
Cogging torque
M
COG
Nm
0.357
Stator mass
m
S
kg
2.2
Rotor mass
m
L
kg
0.881
Rotor moment of inertia
J
L
10
-2
kgm
2
0.139
Phase resistance of winding at 20 °C
R
STR, 20
Ω
6.91
Phase inductance of winding
L
STR
mH
24.5

Table of Contents