1FW6 Built-in torque motors
Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
471
Electrical connection
8
NOTICE
Destruction of the motor if it is directly connected to the three-phase line supply
The motor will be destroyed if it is directly connected to the three-phase line supply.
• Only operate the motors with the appropriately configured converters.
WARNING
Risk of electric shock
If you connect the voltage to the stator as individual component, then there is a risk of
electric shock as there is no touch protection.
• Only connect a voltage if the motor component is installed in the assembled state in the
machine.
WARNING
Risk of electric shock due to incorrect connection
If you incorrectly connect the motor this can result in death, serious injury, or extensive
material damage. The motors require an impressed sinusoidal current.
• Connect the motor in accordance with the circuit diagram provided in this
documentation.
• Refer also to the documentation for the drive system used.

Table of Contents

Other manuals for Siemens SIMOTICS T-1FW6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS T-1FW6 and is the answer not in the manual?

Siemens SIMOTICS T-1FW6 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS T-1FW6
CategoryEngine
LanguageEnglish

Related product manuals