Preparation for use
7.2 Storage
1FW6 Built-in torque motors
Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
469
7.2
Storage
7.2.1
Ambient conditions for long-term storage
Based on EN 60721-3-1 (for long-term storage)
Table 7- 6 Climatic ambient conditions
Lower air temperature limit:
- 5° C (deviates from 3K3)
Upper air temperature limit:
+ 40° C
Lower relative humidity limit:
5 %
Upper relative humidity limit:
85 %
Rate of temperature fluctuations: Max. 0.5 K/min
Condensation:
Not permissible
Formation of ice:
Not permissible
Long-term storage:
Class 1K3 and class 1Z1 have a different upper relative humidity
Storage is only permissible in locations that are fully protected against the weather (in halls or rooms).
Table 7- 7 Biological ambient conditions
Long-term storage:
Class 1B1
Table 7- 8 Chemical ambient conditions
Long-term storage:
Class 1C1
Table 7- 9 Mechanically active ambient conditions
Long-term storage:
Class 1S2
Table 7- 10 Mechanical ambient conditions
Long-term storage:
Class 1M2

Table of Contents

Other manuals for Siemens SIMOTICS T-1FW6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS T-1FW6 and is the answer not in the manual?

Siemens SIMOTICS T-1FW6 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS T-1FW6
CategoryEngine
LanguageEnglish

Related product manuals