Technical data and characteristics
6.2 Data sheets and diagrams
1FW6 Built-in torque motors
Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
191
6.2.2
1FW6060-xxxxx-xxxx
Data sheet 1FW6060-xxB03-xxxx
Table 6- 7 1FW6060-xxB03-0Fxx
Technical data
1FW6060
Symbol
Unit
-xxB03-0Fxx
Boundary conditions
DC link voltage
U
DC
V
600
Water cooling inlet temperature
T
VORL
°C
35
Rated temperature of winding
T
N
°C
130
Data at the rated operating point
Rated torque
M
N
Nm
32
Rated current
I
N
A
4.33
Rated speed
n
N
rpm
633
Rated power loss
P
V,N
kW
0.778
Limit data
Maximum torque
M
MAX
Nm
64.5
Maximum current
I
MAX
A
9.81
Electric motor power at M
MAX
P
EL,MAX
kW
5.91
Maximum speed
n
MAX
rpm
1860
Maximum speed at maximum torque
n
MAX,MMAX
rpm
330
Max. speed without VPM
n
MAX,INV
rpm
1270
No-load speed
n
MAX,0
rpm
932
Torque at n = 1 rpm
M
0
Nm
33.3
Current at M
0
and n = 1 rpm
I
0
A
4.51
Thermal static torque
M
0
*
Nm
23.8
Thermal stall current
I
0
*
A
3.19
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
7.53
Voltage constant
k
E
V/(1000/min)
455
Motor constant at 20 °C k
M,20
Nm/(W)
0,5
1.46
Thermal time constant t
TH
s 75
No. of pole pairs
p
-
15
Cogging torque
M
COG
Nm
0.466
Stator mass
m
S
kg
5.87
Rotor mass
m
L
kg
1.21
Rotor moment of inertia
J
L
10
-2
kgm
2
0.347
Phase resistance of winding at 20 °C
R
STR, 20
Ω
8.9
Phase inductance of winding
L
STR
mH
24.2

Table of Contents

Other manuals for Siemens SIMOTICS T-1FW6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS T-1FW6 and is the answer not in the manual?

Siemens SIMOTICS T-1FW6 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS T-1FW6
CategoryEngine
LanguageEnglish

Related product manuals