EasyManua.ls Logo

Siemens SIMOTICS T-1FW6 - Page 204

Siemens SIMOTICS T-1FW6
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data and characteristics
6.2 Data sheets and diagrams
1FW6 Built-in torque motors
202 Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
Data sheet 1FW6060-xxB07-xxxx
Table 6- 9 1FW6060-xxB07-0Fxx, 1FW6060-xxB07-0Kxx
Technical data
1FW6060
Symbol
Unit
-xxB07-0Fxx
-xxB07-0Kxx
Boundary conditions
DC link voltage
U
DC
V
600
600
Water cooling inlet temperature
T
VORL
°C
35
35
Rated temperature of winding
T
N
°C
130
130
Data at the rated operating point
Rated torque
M
N
Nm
84.3
83
Rated current
I
N
A
4.45
7.9
Rated speed
n
N
rpm
203
464
Rated power loss
P
V,N
kW
1.32
1.33
Limit data
Maximum torque
M
MAX
Nm
166
166
Maximum current
I
MAX
A
9.86
17.8
Electric motor power at M
MAX
P
EL,MAX
kW
7.06
10.8
Maximum speed
n
MAX
rpm
728
1310
Maximum speed at maximum torque
n
MAX,MMAX
rpm
43.3
256
Max. speed without VPM
n
MAX,INV
rpm
497
896
No-load speed
n
MAX,0
rpm
364
656
Torque at n = 1 rpm
M
0
Nm
85.4
85.4
Current at M
0
and n = 1 rpm
I
0
A
4.51
8.13
Thermal static torque
M
0
*
Nm
61.1
61.1
Thermal stall current
I
0
*
A
3.19
5.75
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
19.3
10.7
Voltage constant
k
E
V/(1000/min)
1170
647
Motor constant at 20 °C k
M,20
Nm/(W)
0,5
2.87 2.85
Thermal time constant t
TH
s 75 75
No. of pole pairs
p
-
15
15
Cogging torque
M
COG
Nm
1.19
1.19
Stator mass
m
S
kg
9.37
9.37
Rotor mass
m
L
kg
3.13
3.13
Rotor moment of inertia
J
L
10
-2
kgm
2
0.904
0.904
Phase resistance of winding at 20 °C
R
STR, 20
Ω
15.1
4.69
Phase inductance of winding
L
STR
mH
53.2
16.4

Table of Contents