EasyManua.ls Logo

Siemens SIMOTICS T-1FW6 - Page 210

Siemens SIMOTICS T-1FW6
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data and characteristics
6.2 Data sheets and diagrams
1FW6 Built-in torque motors
208 Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
Data sheet 1FW6060-xxB10-xxxx
Table 6- 10 1FW6060-xxB10-0Kxx, 1FW6060-xxB10-1Jxx
Technical data
1FW6060
Symbol
Unit
-xxB10-0Kxx
-xxB10-1Jxx
Boundary conditions
DC link voltage
U
DC
V
600
600
Water cooling inlet temperature
T
VORL
°C
35
35
Rated temperature of winding
T
N
°C
130
130
Data at the rated operating point
Rated torque
M
N
Nm
117
111
Rated current
I
N
A
7.98
14.6
Rated speed
n
N
rpm
302
708
Rated power loss
P
V,N
kW
1.79
1.86
Limit data
Maximum torque
M
MAX
Nm
231
226
Maximum current
I
MAX
A
17.8
31.5
Electric motor power at M
MAX
P
EL,MAX
kW
11.8
19.1
Maximum speed
n
MAX
rpm
943
1830
Maximum speed at maximum torque
n
MAX,MMAX
rpm
133
471
Max. speed without VPM
n
MAX,INV
rpm
645
1250
No-load speed
n
MAX,0
rpm
472
913
Torque at n = 1 rpm
M
0
Nm
119
116
Current at M
0
and n = 1 rpm
I
0
A
8.13
15.3
Thermal static torque
M
0
*
Nm
85
82.8
Thermal stall current
I
0
*
A
5.75
10.8
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
14.9
7.69
Voltage constant
k
E
V/(1000/min)
900
465
Motor constant at 20 °C k
M,20
Nm/(W)
0,5
3.42 3.26
Thermal time constant t
TH
s 75 75
No. of pole pairs
p
-
15
15
Cogging torque
M
COG
Nm
1.66
1.66
Stator mass
m
S
kg
12
12
Rotor mass
m
L
kg
4.21
4.21
Rotor moment of inertia
J
L
10
-2
kgm
2
1.21
1.21
Phase resistance of winding at 20 °C
R
STR, 20
Ω
6.3
1.85
Phase inductance of winding
L
STR
mH
23.1
5.42

Table of Contents