EasyManua.ls Logo

Siemens SIMOTICS T-1FW6 - Page 216

Siemens SIMOTICS T-1FW6
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data and characteristics
6.2 Data sheets and diagrams
1FW6 Built-in torque motors
214 Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
Data sheet 1FW6060-xxB15-xxxx
Table 6- 11 1FW6060-xxB15-0Kxx, 1FW6060-xxB15-1Jxx
Technical data
1FW6060
Symbol
Unit
-xxB15-0Kxx
-xxB15-1Jxx
Boundary conditions
DC link voltage
U
DC
V
600
600
Water cooling inlet temperature
T
VORL
°C
35
35
Rated temperature of winding
T
N
°C
130
130
Data at the rated operating point
Rated torque
M
N
Nm
172
166
Rated current
I
N
A
8.04
14.8
Rated speed
n
N
rpm
174
442
Rated power loss
P
V,N
kW
2.48
2.65
Limit data
Maximum torque
M
MAX
Nm
339
332
Maximum current
I
MAX
A
17.8
31.5
Electric motor power at M
MAX
P
EL,MAX
kW
12.9
20.3
Maximum speed
n
MAX
rpm
643
1240
Maximum speed at maximum torque
n
MAX,MMAX
rpm
27.6
260
Max. speed without VPM
n
MAX,INV
rpm
439
850
No-load speed
n
MAX,0
rpm
321
622
Torque at n = 1 rpm
M
0
Nm
174
171
Current at M
0
and n = 1 rpm
I
0
A
8.13
15.3
Thermal static torque
M
0
*
Nm
125
122
Thermal stall current
I
0
*
A
5.75
10.8
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
21.8
11.3
Voltage constant
k
E
V/(1000/min)
1320
682
Motor constant at 20 °C k
M,20
Nm/(W)
0,5
4.27 4
Thermal time constant t
TH
s 75 75
No. of pole pairs
p
-
15
15
Cogging torque
M
COG
Nm
2.44
2.44
Stator mass
m
S
kg
16.4
16.4
Rotor mass
m
L
kg
5.97
5.97
Rotor moment of inertia
J
L
10
-2
kgm
2
1.72
1.72
Phase resistance of winding at 20 °C
R
STR, 20
Ω
8.73
2.65
Phase inductance of winding
L
STR
mH
34.2
8.09

Table of Contents