Technical data and characteristics
6.2 Data sheets and diagrams
1FW6 Built-in torque motors
302 Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
Technical data
1FW6160
Symbol
Unit
-xxB07-8Fxx
Data for main motor cooler *)
Maximum dissipated thermal power
Q
H,MAX
kW
2.88
Recommended minimum volume flow
H,MIN
l/min
4.76
Cooling medium temperature increase
ΔT
H
K
8.71
Pressure drop
Δp
H
bar
0.425
Data for precision motor cooler *)
Maximum dissipated thermal power
Q
P,MAX
kW
0.311
Recommended minimum volume flow
P,MIN
l/min
1.84
Cooling medium temperature increase
ΔT
P
K
2.43
Pressure drop
Δp
P
bar
0.425
*) Parallel connection of main and precision motor cooler