Description of the motor
2.3 Technical features and ambient conditions
1FW6 Built-in torque motors
Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
31
For magnetic fields, you must carefully comply with the requirements laid down in the DGUV
regulation 103-013 of the German Social Accident Insurance.
CAUTION
Safety distance to the rotor
The rotor magnetic fields are permanent. If you come into direct bodily contact with the
rotors, a static magnetic flux density of 2 T is not exceeded.
Carefully comply with the DGUV regulation 103-013, Paragraph 14 "Systems with high
static magnetic fields".
WARNING
Electrical shock hazard
Every movement of the rotor compared with the stator and vice versa induces a voltage at
the stator power connections.
If you use defective cable ports, you could suffer an electric shock.
Do not touch the cable ports.
Correctly connect the stator power connections, or insulate them properly.