EasyManua.ls Logo

Siemens SIMOTICS T-1FW6 - Page 335

Siemens SIMOTICS T-1FW6
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data and characteristics
6.2 Data sheets and diagrams
1FW6 Built-in torque motors
Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
333
Table 6- 32 1FW6160-xxB20-0Wxx
Technical data
1FW6160
Symbol
Unit
-xxB20-0Wxx
Boundary conditions
DC link voltage
U
DC
V
600
Water cooling inlet temperature
T
VORL
°C
35
Rated temperature of winding
T
N
°C
130
Data at the rated operating point
Rated torque
M
N
Nm
1470
Rated current
I
N
A
124
Rated speed
n
N
rpm
387
Rated power loss
P
V,N
kW
8.91
Limit data
Maximum torque
M
MAX
Nm
2860
Maximum current
I
MAX
A
282
Electric motor power at M
MAX
P
EL,MAX
kW
95
Maximum speed
n
MAX
rpm
1080
Maximum speed at maximum torque
n
MAX,MMAX
rpm
225
Max. speed without VPM
n
MAX,INV
rpm
741
No-load speed
n
MAX,0
rpm
542
Torque at n = 1 rpm
M
0
Nm
1870
Current at M
0
and n = 1 rpm
I
0
A
160
Thermal static torque
M
0
*
Nm
1350
Thermal stall current
I
0
*
A
113
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
11.9
Voltage constant
k
E
V/(1000/min)
720
Motor constant at 20 °C k
M,20
Nm/(W)
0,5
24.2
Thermal time constant t
TH
s 180
No. of pole pairs
p
-
35
Cogging torque
M
COG
Nm
9.33
Stator mass
m
S
kg
90.6
Rotor mass
m
L
kg
33.7
Rotor moment of inertia
J
L
10
-2
kgm
2
70.1
Phase resistance of winding at 20 °C
R
STR, 20
Ω
0.0806
Phase inductance of winding
L
STR
mH
0.881
Data for main motor cooler *)
Maximum dissipated thermal power
Q
H,MAX
kW
6.69
Recommended minimum volume flow
H,MIN
l/min
11.4
Cooling medium temperature increase
ΔT
H
K
8.47
Pressure drop
Δp
H
bar
2.34

Table of Contents

Other manuals for Siemens SIMOTICS T-1FW6