Technical data and characteristics
6.2 Data sheets and diagrams
1FW6 Built-in torque motors
342 Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
Technical data
1FW6190
Symbol
Unit
-xxB05-1Jxx
-xxB05-2Jxx
-xxB05-5Gxx
Data for main motor cooler *)
Maximum dissipated thermal power
Q
H,MAX
kW
2.73
2.73
2.73
Recommended minimum volume flow
H,MIN
l/min
5.23
5.23
5.23
Cooling medium temperature increase
ΔT
H
K
7.51
7.51
7.51
Pressure drop
Δp
H
bar
0.495
0.495
0.495
Data for precision motor cooler *)
Maximum dissipated thermal power
Q
P,MAX
kW
0.294
0.294
0.294
Recommended minimum volume flow
P,MIN
l/min
1.78
1.78
1.78
Cooling medium temperature increase
ΔT
P
K
2.38
2.38
2.38
Pressure drop
Δp
P
bar
0.495
0.495
0.495
*) Parallel connection of main and precision motor cooler