EasyManua.ls Logo

Siemens SIMOTICS T-1FW6 - Page 352

Siemens SIMOTICS T-1FW6
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data and characteristics
6.2 Data sheets and diagrams
1FW6 Built-in torque motors
350 Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
Table 6- 35 1FW6190-xxB07-8Fxx
Technical data
1FW6190
Symbol
Unit
-xxB07-8Fxx
Boundary conditions
DC link voltage
U
DC
V
600
Water cooling inlet temperature
T
VORL
°C
35
Rated temperature of winding
T
N
°C
130
Data at the rated operating point
Rated torque
M
N
Nm
714
Rated current
I
N
A
57.5
Rated speed
n
N
rpm
377
Rated power loss
P
V,N
kW
4.71
Limit data
Maximum torque
M
MAX
Nm
1390
Maximum current
I
MAX
A
136
Electric motor power at M
MAX
P
EL,MAX
kW
45
Maximum speed
n
MAX
rpm
1060
Maximum speed at maximum torque
n
MAX,MMAX
rpm
212
Max. speed without VPM
n
MAX,INV
rpm
721
No-load speed
n
MAX,0
rpm
528
Torque at n = 1 rpm
M
0
Nm
941
Current at M
0
and n = 1 rpm
I
0
A
78.1
Thermal static torque
M
0
*
Nm
688
Thermal stall current
I
0
*
A
55.3
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
12.6
Voltage constant
k
E
V/(1000/min)
764
Motor constant at 20 °C k
M,20
Nm/(W)
0,5
17.2
Thermal time constant t
TH
s 180
No. of pole pairs
p
-
42
Cogging torque
M
COG
Nm
4.71
Stator mass
m
S
kg
41.2
Rotor mass
m
L
kg
14.6
Rotor moment of inertia
J
L
10
-2
kgm
2
48.6
Phase resistance of winding at 20 °C
R
STR, 20
Ω
0.179
Phase inductance of winding
L
STR
mH
1.62
Data for main motor cooler *)
Maximum dissipated thermal power
Q
H,MAX
kW
3.53
Recommended minimum volume flow
H,MIN
l/min
5.95
Cooling medium temperature increase
ΔT
H
K
8.55
Pressure drop
Δp
H
bar
0.636

Table of Contents

Other manuals for Siemens SIMOTICS T-1FW6