EasyManua.ls Logo

Siemens SIMOTICS T-1FW6 - Page 385

Siemens SIMOTICS T-1FW6
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data and characteristics
6.2 Data sheets and diagrams
1FW6 Built-in torque motors
Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
383
Technical data
1FW6190
Symbol
Unit
-xxB20-0Wxx
Data for precision motor cooler *)
Maximum dissipated thermal power
Q
P,MAX
kW
0.885
Recommended minimum volume flow
P,MIN
l/min
4.75
Cooling medium temperature increase
ΔT
P
K
2.68
Pressure drop
Δp
P
bar
2.79
*) Parallel connection of main and precision motor cooler

Table of Contents

Other manuals for Siemens SIMOTICS T-1FW6

Related product manuals