Technical data and characteristics
6.2 Data sheets and diagrams
1FW6 Built-in torque motors
398 Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
Technical data
1FW6230
Symbol
Unit
-xxB07-1Jxx
-xxB07-2Jxx
-xxB07-5Gxx
Data for main motor cooler *)
Maximum dissipated thermal power
Q
H,MAX
kW
3.45
3.56
3.49
Recommended minimum volume flow
H,MIN
l/min
6.15
6.15
6.15
Cooling medium temperature increase
ΔT
H
K
8.08
8.33
8.15
Pressure drop
Δp
H
bar
0.756
0.756
0.756
Data for precision motor cooler *)
Maximum dissipated thermal power
Q
P,MAX
kW
0.373
0.384
0.376
Recommended minimum volume flow
P,MIN
l/min
2.15
2.15
2.15
Cooling medium temperature increase
ΔT
P
K
2.49
2.57
2.52
Pressure drop
Δp
P
bar
0.756
0.756
0.756
*) Parallel connection of main and precision motor cooler