Technical data and characteristics
6.2 Data sheets and diagrams
1FW6 Built-in torque motors
446 Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
Technical data
1FW6290
Symbol
Unit
-xxB11-7Axx
-xxB11-0Lxx
-xxB11-2Pxx
Data for main motor cooler *)
Maximum dissipated thermal power
Q
H,MAX
kW
5.33
5.33
5.37
Recommended minimum volume flow
H,MIN
l/min
12.8
12.8
12.8
Cooling medium temperature increase
ΔT
H
K
6.01
6.01
6.05
Pressure drop
Δp
H
bar
1.8
1.8
1.8
Data for precision motor cooler *)
Maximum dissipated thermal power
Q
P,MAX
kW
0.575
0.575
0.579
Recommended minimum volume flow
P,MIN
l/min
5.24
5.24
5.24
Cooling medium temperature increase
ΔT
P
K
1.58
1.58
1.59
Pressure drop
Δp
P
bar
1.8
1.8
1.8
*) Parallel connection of main and precision motor cooler