List of signals for the operation screen
Table 8-1 List of signals for the operation screen
Signal Parameter Short name Unit Scaling
(100% = ...)
DO: Vector MV
Factory setting (entry no.)
Speed setpoint upstream of RFG (1) r1114 NSETP 1/min p2000
Output frequency (2) r0024 F_OUT Hz Reference frequen‐
cy
Output smoothed (3) r0032 P_ACT kW r2004
DC-link voltage smoothed (4) r0026 UDC V p2001
Actual speed smoothed (5) r0021 N_ACT 1/min p2000
Actual absolute current smoothed (6) r0027 I_IST A p2002
Motor temperature (7) r0035 T_MOT °C Reference tempera‐
ture
Motor temperature (8) r0037 T_LT °C Reference tempera‐
ture
Actual torque smoothed (9) r0031 M_ACT Nm p2003
Drive output voltage smoothed (10) r0025 C_OUT V p2001
Speed setpoint smoothed r0020 NSETP 1/min p2000
Control factor smoothed r0028 % Reference control
factor
Field-producing current component r0029 A p2002
Torque-producing current component r0030 A p2002
Drive overload
Degree of thermal overload
r0036 % 100% = Shutdown
Speed setpoint motor encoder r0061 N_ACT 1/min p2000
Speed setpoint after filter r0062 N_ACT 1/min p2000
Actual speed smoothed r0063 N_ACT 1/min p2000
Control deviation r0064 1/min p2000
Slip frequency r0065 Hz Reference frequen‐
cy
Output frequency r0066 Hz Reference frequen‐
cy
Output voltage r0072 UACT V p2001
Control factor r0074 % Reference control
factor
Torque-generating actual current r0078 A p2002
Actual torque value r0080 Nm p2003
Fixed speed setpoint effective r1024 1/min p2000
Active motor potentiometer setpoint r1050 1/min p2000
Resulting speed setpoint r1119 1/min p2000
Speed controller output r1508 Nm p2003
I component of speed controller r1482 Nm p2003
Operation
8.2 Operation via the AOP30 operator panel
SINAMICS GM150 6SL3815-2LN41-4AA2
134 Operating Instructions 04/2017