EasyManua.ls Logo

Siemens SINAMICS GM150

Siemens SINAMICS GM150
258 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.7.4 Replacing the operator panel
To replace the operator panel, proceed as follows:
1. Switch off the main circuit-breaker.
2. Open the cabinet.
Power supply
Communication cable
Retaining lug
Figure 9-13 Replacing the operator panel
3. Disconnect the power supply and communication cable at the operator panel.
4. Press the retaining lugs and withdraw the operator panel to the front.
5. Snap on a new operator panel.
6. Attach the connectors for the power supply and communications cable.
Maintenance
9.7 Repairs
SINAMICS GM150 6SL3815-2LN41-4AA2
218 Operating Instructions 04/2017

Table of Contents

Other manuals for Siemens SINAMICS GM150

Related product manuals