5.10.2 Removing the dust protection cover of the closed-loop control cabinet
Note
All Makrolon parts that need to be removed are marked with a red sticker and the item number.
3RV
3RV
3RV
3RV
3RV
3RV
3RV
=
=
① Expanding rivets
② Expanding rivets
③ Expanding rivets
④ Overall configuration, curtain
Pos. 10 Makrolon plate, center front
Pos. 20 Makrolon strip, left
Pos. 60 Makrolon strip, right
Figure 5-7 Dust protection cover, closed-loop control cabinet
1. Using flat-nose pliers, pull off all expanding rivets ① and remove the Makrolon plate
"Pos. 10".
2. Pull off the two expanding rivets ② of the curtain ④ using flat-nose pliers, and remove the
curtain.
3. Using flat-nose pliers, pull off all expanding rivets ③ of the two Makrolon strips "Pos. 20,
Pos. 60" and remove the side strips.
Installation
5.10 Removing the dust protection cover
SINAMICS GM150 6SL3815-2LN41-4AA2
Operating Instructions 04/2017 95