EasyManua.ls Logo

Siemens SINAMICS GM150

Siemens SINAMICS GM150
258 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function diagrams
1590
1690
5060
6300
Note
A simple rise in voltage can be achieved with parameter p6890. Refer to function diagram
6300.
8.4.2 Analog and digital inputs/outputs
8.4.2.1 Analog outputs
The customer terminal block is equipped with two analog outputs for outputting setpoints via
current or voltage signals.
Factory setting:
AO0: Actual speed value 0
AO1: Actual motor current value 0
Adjustable parameters
p4071 Analog outputs, signal source
p4073 Analog outputs, smoothing time constant
r4074 Analog outputs, actual output voltage/current
p4076 Analog outputs, type
p4077 Analog outputs, characteristic value x1
p4078 Analog outputs, characteristic value y1
p4079 Analog outputs, characteristic value x2
p4080 Analog outputs, characteristic value y2
Function diagrams
1840
9572
Operation
8.4 Functions
SINAMICS GM150 6SL3815-2LN41-4AA2
170 Operating Instructions 04/2017

Table of Contents

Other manuals for Siemens SINAMICS GM150

Related product manuals