Programming and Operating Manual (Milling)
258 6FC5398-4DP10-0BA6, 09/2017
Proceed through the steps described earlier to copy the entire program block for POCKET3
and paste it in the line after the above pr
ogram blocks.
Press this softkey to open the win
dow for POCKET3 again. Move the cursor to the input
field for "VARI" and change its value to "12".
Press this softkey to accept the change and open the cycle programming window.
Place the cursor on the end
-of-block character of POCKET3 with the cursor keys and press
this key to enter a new line.
Continue to enter the following program blocks and then
press this key again:
Open the window for CYCLE82 through the following softkey operations:
Enter the desired parameters as follows:
Press this softkey to call this cycle modally.
Press this softkey to confirm your input.
e window for HOLES2 through the following softkey operations: