EasyManuals Logo

Siemens SINUMERIK 810D Commissioning Manual

Siemens SINUMERIK 810D
626 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #132 background imageLoading...
Page #132 background image
Expanding the Operator Interface (BE1) 08/2005
5 Configuring OP Hotkeys and PLC Keys
© Siemens AG, 2005. All rights reserved
BE1/5-126 SINUMERIK 840D sl/840D/840Di/810D HMI Installation and Start-Up Guide (IAM) – 08/2005 Edition
; Activate mapping of the Menu Select key (F10) to
; hotkey 8,
; key has no function
Key8.0 = <empty> ; No reaction assigned
5.1.4 Extensions in HMI Advanced
The machine manufacturer can overload the entries in Keys.ini in directory mmc2
with his own settings. These settings can be entered in one of the following
directories
\user and
\oem
searched earlier during processing. Only deviations in the settings must be stored,
not the complete block.
5.1.5 Action: Special cases in HMI Advanced
HMI Advanced
The ETC key, Action 17, has no effect.
5.1.6 Task, State, and Action: Special cases in HMI Embedded
• The range of values for the Task is limited to between 0 and 15.
• HMI Embedded always selects the last screen combination that was active
before the task change. (State not configured).
• The range of values for State is limited to 0. Only the main menu of the
operating area can be selected.
• The range of values for Action is between 0 and 17 :
SK horizontal 1 to 8,
SK vertical 1 to 8,
Recall and
Etc limited.

Table of Contents

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?