Starting Up HMI Embedded (IM2) 08/2005
3 Communication/Initial Requirements
© Siemens AG, 2005. All rights reserved
IM2/3-20 SINUMERIK 840D sl/840D/840Di/810D HMI Installation and Start-Up Guide (IAM) – 08/2005 Edition
The following methods can be used to create the connections:
Type Connection Path (path entry)
No drive
- -
Local USB Front
(preassigned)
X203
X204
acttcu://0,2
acttcu://2
acttcu://1
USB global X203
X204
Connection to other TCUs
Flash Card
.../user/sinumerik/data/...
CompactFlash
card in the NCU
NW Linux - // Linux ComputerName/Linux
ShareName
NW Windows - // WindowsComputerName/
WindowsShareName
• A numeric setting for DOS (Windows) is made in the "Partition" field.
• Two lines, with a maximum of nine characters each, are available for the
softkey text.
• You must allocate a user name and a password for Windows shares.
If no setting is entered, a default user (PCU20_USER) is entered and a default
password is used.
• No user names or passwords are needed for Linux (NFS) shares and
local/global network paths (USB).
• The first four softkeys for the configured connections are displayed in the
horizontal menu bar in the "Program" and "Services" operating areas, and the
other four softkeys are displayed in the second horizontal menu bar, which can
be opened using the ETC key ">".
• The selection of the drive can be prevented by setting the appropriate access
level.
3.3.2 Network configuration
Settings
The data required for networking the components are entered in the "Network
Configuration" window.
Only the TCP/IP protocol is supported and can be configured within the network
setup screens.