Commissioning HMI Advanced (IM4) 08/2005
2 Functions/Parameterization
© Siemens AG, 2005. All rights reserved
IM4/2-90 SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
2.5.11 IB.INI
Softkey access in the Setup operating area
can be set individually by entering the protection level.
Enter the required protection level in file IB.INI in the
[AccessLevel] section. The operating languages are defined in the [Language]
section.
[ACCESSLEVEL]
RESET =2 ;NCK reset NCK reset
CHG_SCL_SYS=5 ;change scaling system Inch/metric measurements
MASCHDAT =4 ;Machine data Machine data
DRIVE_CFG=2 ;drive configuration Drive configuration
BOOTFILE=2 ;Boot file Boot file
MOT_CTRL=2 ;Motor/Valve selection Motor/valve selection
VIEW=2 ;User views + Display options
User views and
display options
NC_ADDR=2 ;NCK address NCK address
SETUP_SWITCH=2;start-up switch IBN switch
PLC_STATE=3 ;plc state PLC status
PLC_DATE=3 ;plc date PLC date
PLC-CHANGE=2 ;PLC status:
;Sk-Change Value (Change)
;Sk-Reset Value (Reset)
;Sk-Commit Value (Accept change)
Locked by manufacturer
DRIVE_SERVO=2 ;Drives/Servo Drives/servo
SET_COL=3 ;colours Colors
SYST_SETTINGS=4 ;system settings System settings
SET_LANG=2 ;Language Language
SET_BTSS=2 ;Operator panel Operator panel front
OPTION=2 ;Options Options
EDIT=1 ;Editor Editor
DOS=1 ;DOS shell DOS Shell
TOOL_MNG=3 tool management Tool management
FILE=7 ;File functions File functions
PASSWD=3 ;Set/Delete password Set and delete password
CHG_PASSWD=7 ;SK "password ..." SK "password ..."
CHANGE_LANG=7 ;change Language Change language
[LANGUAGE]
;Softkey select language instead of softkey change language in the main
;menu of area setup.
;False: Softkey change language to toggle between the foreground
; and background language.
;True: Softkey select language instead of softkey change language
;to select one of the installed languages. To use this add the ;following values
to the entries of the LANGUAGE section in the ;mmc.ini: