08/2005 Commissioning HMI Advanced (IM4)
2 Setting Functions and Parameters
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
IM4/2-49
Example of a LOGDRIVE.INI file
;-------------------------------------------------- --------
;Copyright (C) Siemens AG 2005 All Rights Reserved.
;----------------------------- -----------------------------
; Drives furnished with ini file
;[Connections]
;ConnectionsNum=8
;Connection<Index>=<Entry>
;AccessMachine<Index>=<Access>
;AccessProgram<Index>=<Access>
;AccessServices<Index>=<Access>
[Connections]
ConnectionsNum=8
Connection4=TCU:\\station1:Front
AccessMachine4=5
AccessProgram4=5
AccessServices4=5
Connection5=TCU:\\station2:X203
AccessMachine5=6
AccessProgram5=6
AccessServices5=6
Connection6=TCU:\\station3:X204
AccessMachine6=6
AccessProgram6=6
AccessServices6=6
Connection7=TCU:\\station4:Front
AccessMachine7=6
AccessProgram7=6
AccessServices7=6
Connection8=\\ef33936c\tmp
AccessMachine8=6
AccessProgram8=6
AccessServices8=6
Softkey label for logical drives
Alarm numbers 89901 to 89908 are evaluated for the softkey texts. Unavailable
texts are replaced by the configured <Entry>.
If a TCU is not configured, the USB entries are ignored. The network drives are not
evaluated unless the corresponding option ($MM_SW_OPTIONS) is set.

Table of Contents

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals