; index of task started by the regie after power on
; (may differ in some circumstances from the default task index,
; which is the task index from [TaskConfiguration] with the lowest number.
PoweronTaskIndex = 0
[StartupConfiguration]
OEM software in the range from 12 to 24 can be started in this section.
The [StartupConfiguration] section is subdivided as follows:
0 to 12 Reserved for expansions by Siemens
12 to 24 Available for OEM applications
25 to 32 Reserved for simulation
33 to 47 Reserved for Siemens applications (in the ADD_ON directory)
Example:
Startup33 = name := ITS, Timeout :=15000
Startup34 = name := HMIVers, Cmdline := "/StartUp", Timeout :=10000
[TaskConfiguration]
; 3. bar
; Task16 = name := oemframe, cmdline := "sysmeter", Timeout := 10000,
; ClassName := "SysMeter", HeaderOnTop := False, PreLoad := False
The 3rd horizontal softkey bar is only displayed if a task or the EXIT button is
assigned to Task 16 or higher in the bar.
; 4th bar : allocated to task 96 - 103
;Task96 = name := oem, Timeout := 10000
;Task97 = name := oem, Timeout := 10000
;Task98 = name := oem, Timeout := 10000
;Task99 = name := oem, Timeout := 10000
;Task100 = name := oem, Timeout := 10000
;Task101 = name := oem, Timeout := 10000
;Task102 = name := oem, Timeout := 10000
;Task103 = name := oem, Timeout := 10000
The 4th horizontal softkey bar is only displayed if a task or the EXIT button is
assigned to Task 96 or higher in the bar.
The Task 50 to Task 87 entries can be used by OEMs.
[CommandToTask]
; only necessary for HMI startup through NCU via command channel
plc_select = #13
Cycles = #14
In this section, you can specify that the HMI will be started from the NCU via the
command channel.
Further information: see “Activating Dialog Screen from NC Program"

Table of Contents

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals