08/2005 Expanding the Operator Interface (BE1)
3 Syntax
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D HMI Installation and Start-Up Guide (IAM) – 08/2005 Edition
BE1/3-67
Access level
ac0
...
ac7
For meaning see Table 3-6
Default setting: AC7
Status
se1 visible
se2 disabled (gray text)
se3 displayed (last softkey used)
Default setting: se1
VS7=("Abort", ac1, se3) ;Define softkey VS7 and assign
;the text "Abort", the access level 1
;and the status "displayed".
VS8=("OK", ac6, se2) ;Define softkey VS8 and assign
;the text "OK", the access level 6
;and the status "cannot be used".
The properties Text, Access Level and Status can be changed in the methods
when the application is running:
SK.st = Text "Abort" ;Softkey, e.g., the text "Abort"
SK.ac = Access level ;Softkey, e.g., with access level 4
SK.se = Status ;Softkey, e.g., with status 2
where:
Access Level
0
...
7
For meaning see Table 3-6.
Status
1 visible
2 disabled (gray text)
3 displayed (last softkey used)
See above for explanation of parameters.