5239 81-4 TRIP (81-4 TRIP) 81 O/U Freq. OUT * ON * LED BO 70 237 2 Yes
5240 81-1: Time Out (81-1 Time Out) 81 O/U Freq. OUT * * * LED BO
5241 81-2: Time Out (81-2 Time Out) 81 O/U Freq. OUT * * * LED BO
5242 81-3: Time Out (81-3 Time Out) 81 O/U Freq. OUT * * * LED BO
5243 81-4: Time Out (81-4 Time Out) 81 O/U Freq. OUT * * * LED BO
6854 >74TC-1 Trip circuit superv.:Trip
Relay (>74TC-1 TripRel)
74TC TripCirc. SP On
Off
**LEDBIBO
6855 >74TC-1 Trip circuit su-
perv.:Breaker Rel (>74TC-1
Bkr.Rel)
74TC TripCirc. SP On
Off
**LEDBIBO
6856 >74TC-2 Trip circuit superv.:Trip
Relay (>74TC-2 TripRel)
74TC TripCirc. SP On
Off
**LEDBIBO
6857 >74TC-2 Trip circuit su-
perv.:Breaker Rel (>74TC-2
Bkr.Rel)
74TC TripCirc. SP On
Off
**LEDBIBO
6858 >74TC-3 Trip circuit superv.:Trip
Relay (>74TC-3 TripRel)
74TC TripCirc. SP On
Off
**LEDBIBO
6859 >74TC-3 Trip circuit su-
perv.:Breaker Rel (>74TC-3
Bkr.Rel)
74TC TripCirc. SP On
Off
**LEDBIBO
6861 74TC Trip circuit supervision OFF
(74TC OFF)
74TC TripCirc. OUT On
Off
* * LED BO 170 53 1 Yes
6865 74TC Failure Trip Circuit (74TC
Trip cir.)
74TC TripCirc. OUT On
Off
* * LED BO 192 36 1 Yes
6866 74TC-1 blocked. Binary input is
not set (74TC-1 ProgFAIL)
74TC TripCirc. OUT On
Off
**LEDBO
6867 74TC-2 blocked. Binary input is
not set (74TC-2 ProgFAIL)
74TC TripCirc. OUT On
Off
**LEDBO
6868 74TC-3 blocked. Binary input is
not set (74TC-3 ProgFAIL)
74TC TripCirc. OUT On
Off
**LEDBO
7104 >BLOCK 50-B1 Backup Over-
Current (>BLOCK 50-B1)
Back-Up O/C SP On
Off
**LEDBIBO6441Yes
7105 >BLOCK 50-B2 Backup Over-
Current (>BLOCK 50-B2)
Back-Up O/C SP On
Off
**LEDBIBO6451Yes
7106 >BLOCK 51-B Backup OverCur-
rent (>BLOCK 51-B)
Back-Up O/C SP On
Off
**LEDBIBO6461Yes
7107 >BLOCK 50N-B1 Backup Over-
Current (>BLOCK 50N-B1)
Back-Up O/C SP On
Off
**LEDBIBO6471Yes
7108 >BLOCK 50N-B2 Backup Over-
Current (>BLOCK 50N-B2)
Back-Up O/C SP On
Off
**LEDBIBO6481Yes
7109 >BLOCK 51N Backup OverCur-
rent (>BLOCK 51N)
Back-Up O/C SP On
Off
**LEDBIBO6491Yes
7110 >50(N)/51(N) BackupO/C Instan-
taneousTrip (>5X-B InstTRIP)
Back-Up O/C SP On
Off
On
Off
* LED BI BO 64 10 1 Yes
7112 >BLOCK Backup OverCurrent
67-TOC (>BLOCK 67-TOC)
Back-Up O/C SP On
Off
**LEDBIBO
7114 >BLOCK Backup OverCurrent
67N-TOC (>BLOCK 67N-TOC)
Back-Up O/C SP On
Off
**LEDBIBO
7115 >BLOCK Backup OverCurrent
67-B1 (>BLOCK 67-B1)
Back-Up O/C SP On
Off
**LEDBIBO
7116 >BLOCK Backup OverCurrent
67N-B1 (>BLOCK 67N-B1)
Back-Up O/C SP On
Off
**LEDBIBO
7117 >BLOCK Backup OverCurrent
67-B2 (>BLOCK 67-B2)
Back-Up O/C SP On
Off
**LEDBIBO
7118 >BLOCK Backup OverCurrent
67N-B2 (>BLOCK 67N-B2)
Back-Up O/C SP On
Off
**LEDBIBO
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log ON/OFF
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 7SD80 and is the answer not in the manual?

Siemens SIPROTEC 7SD80 Specifications

General IconGeneral
BrandSiemens
ModelSIPROTEC 7SD80
CategoryProtection Device
LanguageEnglish

Related product manuals