EasyManua.ls Logo

Siemens SIRIUS 3SK1

Siemens SIRIUS 3SK1
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Explanation DEVICE OUT IN SF
If 1 x two-channel: Simultaneity violated
If two-hand operation: Time monitoring violated.
Green O󹪜 Green 󹪞ashing Red 󹪞ashing
Short-circuit test clock output T1 or T2 Green
2)
O󹪜 Yellow 󹪞ash‐
ing
Red 󹪞ashing
If "monitored start": START button was pressed too long or
has a short-circuit.
Green Yellow 󹪞ash‐
ing
O󹪜 Red 󹪞ashing
Feedback circuit error Green Green 󹪞ashing Green Red 󹪞ashing
1)
Dependent on device status
2)
Green 󹪞ashing DEVICE LED: No startup testing
Error mode
Explanation DEVICE OUT IN SF
Device error
Restart possible by pressing the SET/RESET button.
Red O󹪜
3)
O󹪜
3)
O󹪜
3)
Group error
Restart possible by pressing the SET/RESET button
O󹪜
3)
O󹪜
3)
O󹪜
3)
Red
Group error, cross-circuit at input
Restart possible by pressing the SET/RESET button.
O󹪜
3)
O󹪜
3)
Yellow 󹪞ash‐
ing
3)
Red
System stop
Restart only possible by disconnecting and re-connecting
the operating voltage.
Red O󹪜
3)
O󹪜
3)
Red
3)
On time-delayed devices, the LED 󹪞ashes green/yellow provided the time-delayed outputs are still switched on
Display and diagnostics
11.4 Diagnostics
SIRIUS 3SK1 Safety Relays and 3RQ1 Positively-Driven Coupling Relays
190 Equipment Manual, 05/2021, A5E02526190021A/RS-AE/005

Table of Contents