Operating Manual - English Triax QUATTRO
Copyright Silca 2011 - 69 -
ERROR 4
ERROR Z AXIS
No contact made!
ERROR 5
ERROR X AXIS
No contact made!
A wrong operation has been performed in one of the
machine calibration procedures:
Machine zeros
Clamp calibration
Detection of cutting/decoding plate with a
clamp different from the one required
ERROR 6
ERROR Y AXIS
No contact made!
The machine has detected an unexpected contact during
a movement. The causes could be:
An obstacle during a movement: remove the
obstacle
A long offcut is creating a bridge between the
tool and the fitted key: clean all the swarf off the
machine and repeat the operation.
An offcut is creating a bridge between the
TRACER TOWER and the machine: carefully clean
any swarf off the TRACER TOWER.
ERROR 7
Faulty contact made.
Press START to reset axes!
Check that:
the fitted tool is the one required for the
operation in progress
the length of the tool in use is that set up in the
list of cutters (CALIBRATION -> F2 menu)
ERROR 8
Tool too long or not properly
installed!
The password entered is wrong. Check that you have
entered the password issued by SILCA or apply to SILCA
for a password.
ERROR 9
The number of attempts have
been exceeded!
Restart the machine.